Install and use the automatic decoction packaging machine

Release time锟斤拷2024-12-06 Click count锟斤拷21

1、 Installation of automatic packaging machine decoction equipment

1. The automatic packaging machine decoction equipment does not need to be fixed without vibration during use. Just position the lower box and brake the roller. (Equipped with a stable screw device for the box, the screws should be supported in place)

2. The automatic packaging machine drug equipment has electric heating function. When placing, choose a well ventilated, dry, and clean place.

3. In order to facilitate maintenance, there should be a space of 80mm behind the equipment.

4. Due to the frequent need for water addition and cleaning of the automatic packaging machine decoction equipment, it should be placed in a convenient location for water intake, and the ideal solution should be equipped with a ditch.

5. The automatic packaging machine decoction equipment consumes a large amount of electricity, so a dedicated socket should be used and a professional electrician should be asked to directly connect the power supply to the electrical switch box.

To ensure equipment safety, grounding protection must be done well. At the same time, users are reminded that when using a single-phase three hole socket, they should ensure that the socket has a live wire marked with L and a neutral wire marked with N, which is beneficial for the normal operation of electronic circuits and avoids external interference.

2、 Precautions for using the automatic decoction packaging machine

During the process of decoction, do not add too much water to avoid spilling liquid onto electronic components when boiling, which may cause a short circuit or burn out of the circuit.

2. During the medication process, it is necessary to manually control and master the temperature. When adding water midway, it is absolutely not allowed for cold water to come into contact with the heated glass wall, otherwise it may cause the glass to break.

3. The transmission and electrical control have been precisely adjusted, and users do not need to debug them before use.

When the equipment is running normally, the surface temperature of the medicine tank and packaging head is high, so it is important to prevent burns during operation.

5. Attention must be paid to the service dedicated to decoction to prevent burning and damage to the heating element.

6. After the decoction is completed, the temperature of the medicine container is very high. Do not immediately rinse the glass tube with cold water to avoid the glass tube bursting due to temperature changes.